WATER MANAGEMENT DEVICES

FEATURES

  • Saves Electricity & Water wastage.

  • 24hrs uninterrupted water supply.   

  • No deposition on level sensors for life time.

  • No more dry running & burnouts of pumps.

  • 5 year guarantee.

----------------------------------------------------------------------------------------------------------------

Level Indicator
Model - LI
Indicates five different water levels in the tank i.e. low, ¼th , ½ th, ¾ th and Full.

 

-----------------------------------------------------------------------------------------------------------------------------------------------------

 

Fill Tank Models
Model - LC 22
• 2 level indication of the tank (high & low).

Model - LC 52
• 5 level indication of the tank
• Selectable pump starts level with the help of selector switch.

DESCRIPTION

This unit automatically switches on the pump when the water level goes below the start level (low level) and switches off the pump when the water level reaches the full level (high level) of the tank.

-----------------------------------------------------------------------------------------------------------------------------------------------------

Drain Tank Models
Model-LC 21
2 level indication of the tank (high & low).

Model - LC 51
• 5 level indication of the tank
• Selectable pump start level with the help of selector switch.

DESCRIPTION

This unit automatically switches ON the pump when the water level reaches the high / starts level of the tank and switches OFF the pump when water goes below the low level of the tank.

-----------------------------------------------------------------------------------------------------------------------------------------------------

Auto Booster Pump Controller cum Level Indicator
Model-AB2
• 2 level indication (high & low) of overhead and underground / sump tank.
• Automatic / manual operation switch.

Model-AB5
• 5 level indication of both overhead and underground / sump tank.
• Automatic / manual operation switch.

DESCRIPTION

This model automatically switches on the pump when water is the overhead tank goes below the ½ level and switches OFF the pump when water reaches the full level. The pump gets ON only if the water in the sump tank is above height ¼th level and the pump would go off if the water in the sump tank goes below the low level of the tank. ODD start push button is available for starting the pump at any stage but pump would switch OFF automatically.

-----------------------------------------------------------------------------------------------------------------------------------------------------

Line Sensing Controller
Model-LS

DESCRIPTION

This model senses the water in the main line and switches ON the pump as water supply comes in the line. When water supply goes off, the pump stays ON for the ‘OFF time delay’ (20 seconds) period, if water supply comes back before the completion of 'OFF time delay', then the pump continues to stay ON and timer gets reset. Once OFF time delay is complete then the pump gets ON only after rest time of 20 seconds to avoid frequent switching.

-----------------------------------------------------------------------------------------------------------------------------------------------------

Delivery Sensor
Model-DS

DESCRIPTION

This model senses the water delivery in the tank. The pump is switched ON when power supply is given to the unit, if water doesn’t get delivered within 1½ minutes, the pump switches OFF and the alarm/buzzer sets ON. On pressing the ‘Accept’ push button the buzzer goes OFF and on pressing the ‘Reset’ push button the unit gets reset.