1
ELECTRONIC TIMERS

 

STARDELTA TIMER

 


 

This is used in starter circuit of 3 Phase motors.

It is a On-Delay where the relay gets energised after the set time. During the time the relay is off the winding is connected in star-mode and when the relay gets energised the winding is connected in delta mode through contactors. Time Delay is adjusted from ______________ secs with the help of knob over a linearly caliberated dial. Two 'LED's are provided on top of the unit to indicate supply 'ON' & 'Relay ON' conditions. One change over potential free contact is provided for customer's usage.

Dimensions : Height 105 mm, Base 51 mm x 102 mm
 

 

Top

 

 

 

CYCLIC/CUSTOMISED TIMER

 

 

We make customised timers as per customers requirements including cyclic & sequential timers.

Prices and Dimension varies as per requirements.

 

 

Top

 

 

 

 

 

FLASHER RELAYS

 

 

This relay is used for flashing light signals. The operating relay goes on & off '50' timer per minute' or as per customer requirement. This relay can be applied for traffic control lights, control panels, alarm lights etc.

Dimensions : Height 105 mm, Base 51 mm x 102 mm

 

Top
 

 

 

 

 

 

REVERSING TIMER

 

This is used for cyclic operation of a motor in forward and reverse directions. The unit provides 'ON time' (Adjustable 5-60 secs) and 'OFF Time (5 sec fixed) and two operating relays & initially when the supply gets on, 'OFF time 'starts and then 'ON time' starts. When ON time starts, relay 1 is operated for the set 'ON time' and then off time starts. Again after completion of the OFF Time, ON time starts and relay 2 is operated & then the sequence is repeated. Through relay 1 the motor rotates in one direction and relay 2 the motor rotates in opposite direction.

Dimensions : Height 105 mm, Width 51mm, Length 102mm

Top